Perfect Heating And Plumbing's Guide to
Central Heating Problems
|
|
|
How much will it cost to have a new boiler
installed?
Every heating installation is
different. So to make sure that the right boiler is selected
you need to arrange for an engineer to visit. Generally these
visit are conducted in the evening, so that you don't have to take
time off work. During the visit your existing heating controls
will be visually inspected and you will be advised upon the best way
to make them comply to current Regulations. After the visit you will
receive a free detailed quotation, not an estimate, which is
specific to your requirement.
Call 07802 758166 today to arrange an appointment. |
| |
What is a SEDBUK rating?
The SEDBUK (Seasonal Efficiency of Domestic Boilers in the UK)
rating was developed under the governments Energy Efficiency Best
Practice Programme to provide a fair comparison of different models
of boilers and is a measure of the average annual efficiency under
typical operating conditions.
|
BAND |
SEDBUK RANGE |
|
A |
Above 90% |
|
B |
86-90% |
|
C |
82-86% |
|
D |
78-82% |
|
E |
74-78% |
|
F |
70-74% |
|
G |
Below 70% |
Changes to
the Building Regulations for England and Wales (part L1) which came
into effect on 1st April 2002 to help reduce the United Kingdom's
production of carbon dioxide, require domestic boilers fitted to new
buildings to have a SEDBUK rating of A to D. Non-compliant boilers
may be fitted into existing buildings until 31st August 2002.
The use of
Cleaner to commission new systems followed by treatment with System
Inhibitor will ensure that the efficiency rating is maintained. |
| |
Why are some of my radiators
hotter than others?
This usually means
that your central heating system is incorrectly balanced. This
is both inefficient and effect your comfort. An engineer will
be able to re-balance your system and suggest any other
improvements.
|
| |
My combination boiler produces
a poor flow of hot water?
Older
combination boilers often have a poor flow rate compared to newer
models. This is due to design and age of your boiler.
The problem can be made worse over time by lime scale build up
inside the boilers heat exchanger. It is recommended that you
arrange for an engineer to call.
Call 07802 758166 today to arrange an appointment.
|
| |
Why do my radiators not get hot
to the touch?
Check that your boilers
thermostat to set to maximum and that your room thermostat is set to
a minimum of 20. |
| |
Why are some of my radiators
hot at the top and cold at the bottom?
This
in normally do to sludge build up in the bottom of the radiator.
This can be removed by powerflushing the entire heating system.
However the cause of the sludge should be identified , for example
you may have a leak, your system may be "over pumping" or you may
not have a lid upon you central heating make-up cistern. These
can be easily rectified by an engineer. Please read about
powerflushing within the Heating & Boiler section.
|
| |
Why are some of my radiators
cold at the top and hot at the bottom?
This is normally due to air being trapped in the top of the
radiator. The air can be released by using a radiator key.
Be very careful when releasing the vent screw that you don't unwind
it to far so that it falls out. Also when re-tightening the
vent screw only do it up finger tight so that you do not break the
vent screw off inside the radiator.
|
| |
My Feed & Expansion tank contains 'foulant'. Will System Inhibitor
remove this?
System Inhibitor is a mild
biocide, but if your feed and expansion tank is contaminated with a
jelly-like substance that smells (which could be bacteria, algae,
fungal growth or yeast formation) then you should bail out the tank
and rinse with a 10% solution of household bleach. Observe good
personal hygiene practice.
The expansion of warm water
into the feed and expansion tank, together with the ventilated loft
space means that the ideal environment has been provided for
airborne bacteria and spores to thrive.
Although one might expect the natural 'pasteurization' effect (15-30
minutes at 60°C) within an active central heating system to kill off
these bugs, their effect on water quality can be detrimental. Its
therefore important to remove this contamination.
Organic matter in their metabolism
produce change in the composition of water; algae remove carbon
dioxide and give off oxygen while other organisms consume oxygen.
Decay of organic matter may also generate corrosive amino-acids.
Sulphite Reducing Bacteria (SRB's)
for example which produce hydrogen sulphide cause corrosion directly
but are only active during periods of inactivity. (Over the summer
for example). There are, however, mesophillic and thermophillic
SRB's which can survive and grow in hot water.
Treating a clean system with System
Inhibitor and covering the feed and expansion tank with a close
fitting lid should prevent reoccurrence of the contamination. |
| |
Does my water quality affect my central heating system?
In a word, YES!
Hard water tends to be scale forming, whereas soft water tends to be
corrosive. Either way, an inhibitor is beneficial.
Levels of calcium and
magnesium in the domestic supply vary throughout the country. There
is no UK maximum limit for hardness. Higher levels of hardness will
be found in areas where rain-water percolates through limestone
rock. Granite or surface water supplies will tend to be softer.
If white deposits form on
your kettle element, or white scum floats in the bath, these are
indicators of scale. Heating causes dissolved bicarbonates to form
solid carbonate limescale and is more likely to happen when
temperatures exceed 60°C. A simple test can be carried out with
vinegar. Scale will fizz slightly and give off bubbles.
Because your central
heating system re-circulates the same water, there is little
opportunity for new hardness salts to enter the system, unless you
have a leak! Unfortunately the small amount of hardness will tend to
deposit itself on the hottest part of the system, resulting in
irritating noises.
Hardness is measured in parts per
million (ppm) of calcium carbonate (CaCO3 ).
See table
below for the description of hardness levels:
|
Description
|
Hardness ppm
|
|
Soft
|
|
|
Moderately Soft
|
|
|
Slightly Hard
|
|
|
Moderately Hard
|
|
|
Hard
|
|
|
Very Hard
|
|
In soft water areas the
installation of System Inhibitor will protect the metals from the
corrosive nature of the water and in hard water areas, the scale
inhibitor within System Inhibitor
will control hardness. In very hard areas it is recommended to
additionally install System Silencer. |
| |
My pipes creak and tick
If the noise
emanates from under the floor or within the walls, away from the
boiler, then the most likely cause will be that the pipe's free
movement has been constrained and the noise is thermal stress.
(Radiators may also be heard to creak in their brackets).
Pipes expand
when hot and contract as they cool.
For example,
each 1-metre length of copper pipe-run will increase axially by 1
millimetre over a 60°C temperature gradient.
Adding
treatment chemicals will not break the laws of physics!
If you wish to
eliminate the noise then you have little choice but to lift the
floorboards or break into the wall and make provision for movement.
Pipes that run parallel to joists should be secured with clips that
allow movement whereas pipes that run across joists should sit in
large enough notches to accommodate felt lagging to cushion against
rubbing.
Alternatively
you might consider adjusting your programmer so that your system
comes up to temperature (and cools) at times during the day when the
creaking noises will be less obtrusive.
Humming noises
usually emanate from the circulator pump. Vibration noises of this
type can be caused by an ineffectual mounting bracket or wear to the
impellor shaft/bearing.
|
| |
What is Benchmark?
Benchmark is an initiative launched to improve
quality within the heating industry. All competent heating
installers should be aware of benchmark standards. Virtually every
boiler sold in the UK comes with its own log book which should be
fully completed by the installer and handed to you once your new
boiler has been installed and commissioned. This log book becomes
your certificate of compliance with all relevant building
regulations and also is your guarantee. No certificate no guarantee.

|